Installation Instructions
Du ct---F r ee Sys tem s
Cooling Only and Heat Pump Units (Size 018---060)
Acces so ry Wind Ba ffl e Kit
2To5NominalTons
NOTE: Read and become familiar with these instructions before
beginning installation.
SAFETY CONSIDERATIONS
Installing and servicing air--conditioning equipment can be
hazardous due to system pressures and electrical components. Only
trained and qualified personnel should install or service
air-- conditioning equipment. When working on air-- conditioning
equipment, observe the precautions provided in literature, tags, and
labels attached to the unit.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and
National Electrical Code (NEC), ANSI/NFPA 70, Canadian
Electrical Code CSA C22.1 and local codes and ordinances for
special requirements.
Recognize safety information. This is the safety--alert symbol
!
!
.
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury.
Understand these signal words: DANGER, WARNING, and
CAUTION. These words are used with the safety--alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies hazards
which could result in personal injury o r death. CAUTION is used
to identify unsafe practices which may result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before beginning any modification or installation of this kit,
be sure the main electrical disconnect is in the OFF position.
Ensure power is disconnected to the fan coil unit. On some
systems both the fan coil and the outdoor unit may be on the
same disconnect. T ag the disconnect switch with a suitable
warning label. There may be more than one disconnect.
!
WARNING
GENERAL
These instructions cover the installation of the accessory wind
baffle kit on cooling only, heat pump, and multi--split units. The kit
is used with horizontal discharge outdoor units to provide
improved unit operation in areas with high winds.
INSTALLATION
Refer to Table 1 for kit contents and usage.
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
To avoid compressor damage, never turn unit on its side or
top when installing kit components.
CAUTION
!
STEP 1 Install Z Brackets
1. Remove existing screw from outdoor unit top cover. See
Fig. 1.
2. Position top Z bracket between grille and top cover. Be sure
shorter top bend of Z bracket slips between top cover flange
and metal strip behind top cover flange. See Fig. 1.
3. Reinstall screw removed in Step 1, inserting it through
screw hole in top cover and Z bracket. Fasten screw into
grille.
4. Install bottom Z bracket in basepan corner, following same
procedures. Be sure shorter top bend of Z bracket slips
between basepan flange and metal strip behind basepan
flange. See Fig. 1.
STEP 2 Join End and Front Baffles
1. Using the screws provided in kit, join the 2 baffles at their
center holes. See Fig. 2. Tighten screws securely .
STEP 3 Attach End Baffle Flange
1. Remove 3 screws from coil cap. See Fig. 1.
2. Install end baffle flange to Z bracket and use 3 screws re-
moved in Step 1 to secure one end. See Fig. 1 and 2. End
baffle flange fits against coil cap. Tighten screws snugly. Do
not overtighten.
STEP 4 Attach Front Baffle Flange
1. Remove 2 screws from access panel. See Fig. 1.
2. Install front baffle flange using 2 screws removed in Step 1.
Front baffle flange overlaps end baffle flange where Z
brackets are installed. With baffle in place, tighten all screws
snugly. Do not overtighten.